Holders

Immersion type  /  Drop-in Type  /  Flow-through Type

Immersion type

CH-101 Series

ModelCH-101CH-101PCH-101PF
Holder materialPPPVCPVDF
Sample
condition
Temperature-5 to 80℃-5 to 50℃-5 to 100℃
PressureAtmospheric pressure
Flow rateLess than 2m/sec
Holder length (m)0.5・1.0・1.5・2.0・2.5・3.0
pH electrodes that can
be combined
6108・6109・
6110
6108・6109・
6110・6151・
6152
6108
Combination may not be possible depending on the properties of sample water, etc.
Brackets and loose
flanse that can be
combined
BA-2A・BA-1S
MB-10・FK-1
FK-1P・FK-1S
BA-2A・BA-1S
MB-10・FK-1
FK-1P・FK-1S
BA-2A・BA-1S
MB-10
A support pipe(SP-60) is required when fixing the immersion holder of 2m or more.
Cleaner that can be
combined
UCH-101・UCH-111・JCH-101・JCH-121A
BCH-101・BCH-121・BCH-101J・BCH-121J
Combination may not be possible depending on the properties of sample water, etc.

HIBP Series

ModelHIBP
Holder materialPP
Sample
condition
Temperature-5 to 80℃
PressureAtmospheric pressure
Flow rateLess than 2m/sec
Holder length (m)0.5・1.0・1.5・2.0・2.5・3.0
pH electrodes that can
be combined
6171・6172・6173・6174
Combination may not be possible depending on the properties of sample water, etc.
Brackets that can be
combined
MB-10
Cleaner that can be
combined
None

HIBS Series

ModelHIBS
Holder materialSUS316
Sample
condition
Temperature-5 to 100℃
PressureAtmospheric pressure
Flow rateLess than 2m/sec
Holder length (m)0.5・1.0・1.5・2.0・2.5・3.0

pH electrodes that can
be combined

6171・6172・6173・6174
Combination may not be possible depending on the properties of sample water, etc.
Brackets and loose
flanse  that can be
combined
MB-10・RFS1
Cleaner that can be
combined
None

Drop-in Type

NH-10 Series

ModelNH-10PNH-10S
Holder materialPVCSUS316
Sample
condition
Temperature  
PressureAtmospheric pressure
Flow rateLess than 2m/sec
Holder length (m)2.0・3.0・4.0
pH electrodes that can
be combined
8300
Adaptor (P-AD) is required for pH-electrode fixation.
Brackets that can be
combined
MH-100

Flow-through Type

CF-251 Series

ModelCF-251CF-251PCF-251S
Holder materialPPPVCSUS316
Ambient temperature-5 to 60℃-5 to 50℃-5 to 60℃
Sample
condition
Temperature-5 to 80℃-5 to 50℃-5 to 100℃
Sample must not be frozen
PressureAtmospheric pressure
Flow rate0.3 to 10L/min
The bore of the
connection to the
sample water
JIS 10K 25A FF flange
pH electrodes that can
be combined
6108・6109
6110
6108・6109
6110・6151
6152
6108

CF-251-T Series

ModelCF-251-TCF-251P-TCF-251S-T
Holder materialPPPVCSUS316
Ambient temperature-5 to 60℃-5 to 50℃-5 to 60℃
Sample
condition
Temperature-5 to 80℃-5 to 50℃-5 to 100℃
Sample must not be frozen
PressureAtmospheric pressure
Flow rate0.3 to 10L/min
The bore of the
connection to the
sample water
JIS 10K 25A FF flange
pH electrodes that can
be combined
6108・6109
6110
6108・6109
6110・6151
6152
6108

CF-301 Series

ModelCF-301CF-301PCF-301S
Holder materialPPPVCSUS316
Ambient temperature-5 to 60℃-5 to 50℃-5 to 60℃
Sample
condition
Temperature-5 to 80℃-5 to 50℃-5 to 100℃
Sample must not be frozen
Pressure-5 to 40℃
 :0.30MPa
40 to 60℃
 :0.22MPa
60 to 80℃
 :0.15MPa
-5 to 40℃
 :0.30MPa
40 to 50℃
 :0.15MPa
5 to 40℃
 :0.30MPa
40 to 60℃
 :0.25MPa
60 to 80℃
 :0.20MPa
80 to 100℃
 :0.15MPa
Flow rate0.3 to 10L/min
The bore of the
connection to the
sample water
JIS 10K 25A FF flange
Pressurizing inlet for holder's internal pressureRc 1/8
pH electrodes that can
be combined
61086108・6151
6152
6108

CF-401S Series

ModelCF-401S
Holder materialSUS316
Ambient temperature-5 to 60℃
Sample
condition
Temperature-5 to 100℃
Sample must not be frozen
Pressure-5 to 40℃:0.60MPa
40 to 60℃:0.46MPa
60 to 90℃:0.26MPa
90 to 100℃:0.20MPa
Flow rate0.5 to 10L/min
The bore of the
connection to the
sample water
JIS 10K 25A FF flange
Pressurizing inlet for holder's internal pressureRc 1/8
pH electrodes that can
be combined
6108

CF-501 Series

ModelCF-501CF-501PCF-501S
Holder materialPPPVCSUS316
Ambient temperature-5 to 60℃-5 to 50℃-5 to 60℃
Sample
condition
Temperature-5 to 80℃-5 to 60℃-5 to 100℃
Sample must not be frozen
PressureAtmospheric pressure
Flow rate0.3 to 10L/min
The bore of the
connection to the
sample water
JIS 10K 25A FF flange
pH electrodes that can
be combined
61746171・6172
6173・6174
6174