PSA300*

PSA-300 image
PSA-300 image

Static Image Analysis System Particle Size

*Available in the Americas. For additional information, please contact us.

The HORIBA PSA300 is a state of the art turn-key image analysis solution. Seamless integration of Clemex's powerful particle characterization software and an automated microscope with high-resolution camera creates an intuitive, easy-to-use imaging workstation. Addressing a need in the field of particle characterization, the PSA300 is a versatile particle size and particle shape analysis tool that can be used in a wide range of applications in the pharmaceutical industries and material science. It is a turn-key solution for labs that want to maintain an analytical microscopy environment with minimum intervention by the operator yet still yield maximum detail in the results.

Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

Selection of countries and territories where this product is available:
Afghanistan,Antigua and Barbuda,Argentina,Armenia,Australia,Azerbaijan,Bahamas,Bangladesh,Barbados,Belize,Bhutan,Bolivia,Brazil,Brunei,Cambodia,Canada,Cayman Islands,Chile,China,Colombia,Costa Rica,Cote d'Ivoire,Dominica,Dominican Republic,Ecuador,El Salvador,French Guyana,French Polynesia,FYROM (North Macedonia),Grenada,Guadeloupe,Guatemala,Guyana,Haiti,Honduras,Hong Kong SAR of China,India,Indonesia,Jamaica,Japan,Kazakhstan,Korea (South),Kosovo,Kyrgiyz Republic,Laos,Madagascar,Malaysia,Maldives,Martinique,Mayotte,Mexico,Mongolia,Myanmar,Nepal,New Caledonia,New Zealand,Nicaragua,Pakistan,Panama,Paraguay,Peru,Philippines,Republic of the Congo,Reunion,Russia,Saint Helena,Saint Kitts and Nevis,Seychelles,Sierra Leone,Singapore,Sri Lanka,St. Lucia,St. Vincent and the Grenadinas,Suriname,Taiwan,Tajikistan,Thailand,Trinidad and Tobago,Turkmenistan,United States,Uruguay,Uzbekistan,Venezuela,Vietnam
View the complete list here.

  • Particle shape information  –  Industry experts, especially pharmaceutical, are now looking to characterize particle shape in addition to particle size, to gain a better understanding of how shape can effect the various properties of a product. More are recognizing the significance of particle size and shape as well as their impact on the physical characteristics of many particulate materials. Process problems with drug substances can often be attributed to the particle size or shape of the active material.
  • Sensitivity and accuracy  –  PSA300 features excellent resolution and detection of micronized particles as small as 0.5 microns. Our unique automated calibration routine assures complete validation of measurement accuracy in accordance with NIST standards. Particle volume determination is based on absolute 2D measurements and thus not limited to spheroids. Accurate volume measurements can be performed on elongated cylinders, acicular or irregular shaped objects.
  • Repeatability  –  Microscope parameters and camera settings are saved as properties in the routine associated with each sample. In conjunction with an automated workstation, an image analysis routine can be executed multiple times with no deviation from the initial results. This guarantees reproducibility and traceability of analysis, ensuring accurate results and conforming to 21 CFR Part 11 requirements.
  • High Throughput  –  Data collection is achieved through multiple field analysis using a Clemex 4-slide sample holder and motorized stage. Our robotic image analysis system will allow the user to measure large number of slides simultaneously without any operator intervention.
  • Results Management  –  PSA300 automatically calculates various measurements simultaneously on thousands of individual particles. It is capable of generating statistically significant results in an amazingly short time. The powerful report generator allows speedy data processing and flexible reporting capabilities.
  • Security and Compliance  –  PSA300 allows the management of user rights, audit trail of critical interventions, electronic signatures as well as overwrite protection of all electronic documents produced by PSA300 imaging workstation (images, stage patterns, image analysis routines, raw binary data, image analysis report in PDF). Traceability is assured by saving all analysis settings, data, results, and images (if required) in the same protected file. All of these security features are designed to conform to regulatory requirements such as FDA 21 CFR part 11 ensuring data integrity.

Size Range0.5-1000 µm
Objectives2.5X, 5X, 10X, 20X and 50X.
AutomationComputer controlled Motorized nosepiece, Computer controlled Motorized condenser, Computer controlled Motorized focus, 0.05mic/step, Motorized stage 215 x 75 mm travel, 0.5 mic/step, CLEMEX Motorized stage controller assembly.
Measurement TimeBetween 2 and 30 minutes depending on particle size and number of particles analyzed.

Principle of Operation

The use of automated image analysis is increasingly being recognized as an attractive technique to characterize particle shape and size distribution. Traditional methods, such as laser diffraction, although highly efficient, give limited information on particle shape proving image analysis as the best tool for performing particle analysis.

 

Accessories

Disperser Unit –  An automated sample disperser subjects powder samples to a controlled quantity of force by subjecting the sample to a burst of air as a vacuum is released. The sample disperser breaks agglomerates and assures an even spread of sample across the slide. Unit includes disperser column, two slides base, high vacuum dry pump assembly, and USB computer control unit and software.

Particle Size and Shape for Ointments and Creams
This study utilizes the PSA300 automated image analysis system to quantify the size and shape of various ointments and creams.
Particle Size and Shape of Abrasives
The behavior of an abrasive material is influenced by the hardness, size, and shape of the particles. A harder particle will be more aggressive in altering the surface of the work piece. Larger particles generate higher impact force removing the material surface quicker and producing a heavier texture. Particle shape also plays a role.
Size and Shape Characterization of Pharmaceutical Active Ingredients
This application note summarizes the reasons why static image analysis is becoming a popular technique for characterizing APIs.
Metal Powder Size Measurement
Virtually any metal can be made into a powder through processes including atomization, electrolysis, chemical reduction, and size comminution. The metal powder can then be used to fabricate parts from simple to complex shape. The technique and study of these processes is known as powder metallurgy, a field of study well acquainted with particle characterization. The size distribution and shape of the powder metal particles influences the physical properties of the parts created.
Pharmaceutical Aerosol Applications
Pharmaceutical aerosols including metered-dose inhalers (MDIs) and dry powder inhalers (DPIs) are devices that deliver a specific quantity of drug to the lungs. The particle size distribution and shape of the delivered dose is more critical for inhalation aerosols than for most other conventional drug products because these factors greatly influence the deposition profile in the lungs of the patient.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

ViewSizer 3000

Simultaneous Multi-Laser Nanoparticle Tracking Analysis (NTA)

ANALYSETTE 28 ImageSizer*
ANALYSETTE 28 ImageSizer*

Dynamic Image Analysis

Eyecon2™*
Eyecon2™*

Direct Imaging Particle Analyzer

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

Nanoparticle Analyzer

Partica CENTRIFUGE
Partica CENTRIFUGE

Centrifugal Nanoparticle Analyzer

Partica LA-960V2
Partica LA-960V2

Laser Scattering Particle Size Distribution Analyzer

Partica mini LA-350
Partica mini LA-350

Laser Scattering Particle Size Distribution Analyzer

PD10
PD10

Reticle / Mask Particle Detection System

RP-1
RP-1

Reticle/Mask Particle Remover

SA-9600 Series
SA-9600 Series

BET Flowing Gas Surface Area Analyzers

SA-9650 Series
SA-9650 Series

BET Surface Area Analyzers

ViewSizer 3000
ViewSizer 3000

Simultaneous Multi-Laser Nanoparticle Tracking Analysis (NTA)

ANALYSETTE 28 ImageSizer*

Dynamic Image Analysis

Eyecon2™*

Direct Imaging Particle Analyzer

Corporate