VG-200S

Capacitance Manometer

Absolute pressure measurement is crucial for most of vacuum processes in various industries including Semiconductor, FPD, HDD, PV and Coating. A capacitance manometer determines the total pressure from the deformation of the diaphragm that occurs when a pressure difference is applied to both side of the diaphragm. The strong points of the capacitance manometer over other methods are:

•Higher precision

•Less gas dependence in pressure output

•Relatively resistant to corrosive gases

Segmento: Semiconductor
Fabricante: HORIBA STEC, Co., Ltd.
  • Compact self heating design
  • Original signal processing method for accurate measurement
  • SUS316L diaphragm
  • Selectable from temperature-controlled (55, 100°C) or non-heating type
  • ONE PUSH ReZero
  • Power requirements /-15VDC or 24VDC
  • CE & RoHS compliant
ModelVG-211SVG-221S
F.S. measurement range133.32 Pa (A)1.3332kPa (A), 13.332kPa (A), 133.32kPa (A)133.32Pa (A)1.3332kPa (A), 13.332kPa (A), 133.32kPa (A)
Sensor temperature *1Amb. (25°C)55℃ / 100°C
Accuracy *20.5% R.S.0.25% R.S.0.5% R.S.0.25% R.S.
Resolution0.03% F.S.0.01% F.S.0.03% F.S.0.01% F.S.
Zero temperature coefficient0.01% F.S./°C0.005% F.S./°C0.005% F.S. /°C0.0025% F.S. /°C
Span temperature coefficient0.05% R.S./°C0.03% R.S./°C0.03% R.S. /°C0.02% R.S. /°C
Response time< 60msec
Operating temperatue *310-50°C
Wetted materialsSUS316L
Pressurization limit300kPA (A)350kPa (A)300kPa (A)350kPa (A)
Output signal0-10VDC Load resistance: 10kΩ or more
I/O connectorD-Sub 15pin
Power supply voltage 15VDC±5%、0.1A max. -15VDC±5%、0.1A max 15VDC±5%, 0.6Amax. -15VDC±5%, 0.6Amax.
24VDC±5%, 2.4W max.24VDC±5%, 22W max.
warm-up time15 minutes60 minutes (55°C temp. control type)
120 minutes (100°C temp. control type)
Open collector outputRated voltage: 30V Rated current: 50mA
Re-Zero input *4Now-voltage contact input Contact open voltage: 13V Maximum contact current: 1.3mA
Standard fitting *5KF16, 1/2 inch VCR Female, ICF34, 1/4 inch VCR Female

*1 The sensor temperatureis indicated on the nameplate. Please specify the sensor temperature when ordering.
*2 Linearity, hysteresis, and repeatability are included. (at the ambient temperature of 25°C)
*3 Under the specified environmental conditions, when there are heat sources around the product or when some products are placed in close formation, the ambient temperature may exceed the specified ambient temperature.
*4 The adjustable range of the zero point is ± 5%.
*5 Please specify the fitting when ordering.

 

Sterilization Process in Food and Beverage Manufacturing
Vacuum Monitoring in Dryer Equipment for Freeze Dry in Pharmaceuticals and Medicine Manufacturing

Pedido de Informação

Você tem alguma dúvida ou solicitação? Utilize este formulário para entrar em contato com nossos especialistas.

* Esses campos são obrigatórios.

Related products

IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LE Series

Large Flow Liquid Source Vaporization Control System

LF-F/LV-F Series

Digital Liquid Mass Flow Meters / Controllers

Micropole System QL Series

Quadrupole Mass Analyzer

SEC-E Series

Mass Flow Controller

SEC-N100 Series

Digital Mass Flow Controller

SEC-Z500X Series

Multi Range/Multi Gas Digital Mass Flow Controller

EC-5000 Series
EC-5000 Series

Exhaust Pressure Controller

GR-300 Series
GR-300 Series

Wafer Back Side Cooling System

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PV Series
PV Series

Piezo Actuator Valve

UR-Z700 Series
UR-Z700 Series

Digital Automatic Pressure Regulator

CRITERION D500

Pressure Insensitive Mass Flow Module

D700MG

High Speed & Precision Pressure Insensitive Mass Flow Module

D700T

Best Performance Pressure Insensitive Mass Flow Module

D700uF

Micro Flow Pressure Insensitive Mass Flow Module

D700WR

Wide Range Pressure Insensitive Mass Flow Module

DZ-100

Ultra-thin Mass Flow Module

Corporate