File:P3DT AFM.jpg
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
Size of this preview: 495 × 599 pixels. Other resolutions: 198 × 240 pixels | 396 × 480 pixels | 634 × 768 pixels | 846 × 1,024 pixels | 1,500 × 1,816 pixels.
Original file (1,500 × 1,816 pixels, file size: 1.09 MB, MIME type: image/jpeg)
File information
Structured data
Captions
Summary
[edit]DescriptionP3DT AFM.jpg | AFM images of regio-random poly(3-decylthiophene-2,5-diyl) (P3DT) adsorbed on the surface of hBN. a An overview height scan of P3DT assembled on hBN, scan rate 6.51 Hz, 1024 × 1024 px; inset shows lattice frequency shift image of hBN acquired in FM-AFM tapping mode, scan rate 39 Hz, 512 × 512 px; both images were acquired with the same Arrow UHF probe oscillating at fundamental frequency of 1.42 MHz. b A selected area from scan a showing individual PT molecules and low-contrast features associated with decyl side chains. c Profile along the line highlighted in a showing molecule-to-molecule separation of 1.95 nm. d, e Structural models for P3DT assembly on hBN with corresponding dimensions calculated using the AM1 semi-empirical method. f Ultra-high-resolution AFM height scan of three individual P3DT molecules. Image (f) was acquired using third eigenmode of Multi75Al-G probe oscillating at 1.255 MHz and a setpoint of 24 mV. Scan rate 19.5 Hz, 1024 × 1024 px |
Date | |
Source | https://www.nature.com/articles/s41467-019-09571-6 |
Author | Vladimir V. Korolkov ew al. |
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 02:26, 19 August 2023 | 1,500 × 1,816 (1.09 MB) | Materialscientist (talk | contribs) | {{Information |Description=AFM images of regio-random poly(3-decylthiophene-2,5-diyl) (P3DT) adsorbed on the surface of hBN. a An overview height scan of P3DT assembled on hBN, scan rate 6.51 Hz, 1024 × 1024 px; inset shows lattice frequency shift image of hBN acquired in FM-AFM tapping mode, scan rate 39 Hz, 512 × 512 px; both images were acquired with the same Arrow UHF probe oscillating at fundamental frequency of 1.42 MHz. b A selected area from scan a showing individual PT molecules and... |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Hidden category: