Playground for my GDL objects. Acts like pile of snippets/Demo objects. So if you see something of interest: Go and grab it, salvage what you need and use it in your own projects.

No Maintenance Intended
No support, no maintenance. . Your mileage may vary.
It's just for learning, folks.


Check out my production objects and find out how you can boost your productivity while programming your own GDL objects for Archicad!


Sort the values of an array, so they appear in alphanumeric order.

Directly changing the case is not directly possible with GDL. This is partly due to the fact that GDL is generally case-insensitive.

Test this statement with the following code:

if "ABCDE" = "abcde" then print "Same"
!` will output "Same"

Why the demo object works:
We loop our way through every character in the string and replace it manually with the chosen case version. For this we need to have two conversion strings to be set up first, with the corresponding characters at the same place.

Determine if the object is run alone or CALLed from another object.

The SPLIT command expects float numbers inside of strings to be in the American notation, ergo with a "dot" instead of a comma (as done in the European decimal notation).

Sadly, there is no native way to delete/pop items from an array. This makes it necessary to do a bit of juggling.

Dependencies

Explains how dynamic hotspots (in an array) work.
Basically, it's this:

!--- Param script ---! 
values "n_in_array"   1, 2, 3, 4, 5, 6, 7, 8, 9, custom, range [1,)

dim setval[]
for i=1 to n_in_array
	if i > vardim1(array_val) then
		setval[i] = 0
	else
		setval[i] = array_val[i]
	endif
next i

array_val = setval

parameters   array_val = array_val

Compatibility Dependencies

See full article on how to detect (kinda) the language the user might speak.

Compatibility Dependencies

DEMO for a image filter process. The filter (via a prefix) serves to limit the otherwise very large and performance-heavy image selection in a GDL object.

A subroutine for visual debugging (when you're lost in 3D).

Demonstrates the unique ability of project2{4}: Overriding the attributes and e.g. changing the contour to a dashed line type.

Compatibility Dependencies

This object is a demo for a modeling case where you have two vectors with their angles and need a rounded corner where those vectors meet. How to get the coordinates? The solution is to offset the vectors by the radius and offset their intersection point back onto the original vectors.

Note: uses the "BasicGeometricCalc" macro, which is now deprecated. Could easily be rewritten to use the newer, dict-based "BasicGeometry" macro.

Rounded Prisma

Sort numeric values on the buffer and ignore duplicate values.
We solve this problem by comparing two values and switch them and repeat this until is_unsorted is false.

Sort the values from the buffer randomly into an array.

Dependencies

Demo code for a way to ensure there are no duplicate items inside an one-dimensional array.

Shows a way of identifying which value in an array has changed last by user input by "shadowing" the whole parameter and performing a task afterwards.

Demonstrates how you are able to substitute the param that is shown in the tracker, so you can steer another parameter.

Compatibility Dependencies

If you ever were in need to dial from Archicad. Just a Demo object to explore some concepts, e.g. using a hotspot based interface to let the user input things when in plan.
Note: Object doesn't actually call anybody, sadly. 😢


Further references

I dump some GDL insights here.

Basic Stuff

LP_XML Converter

Get yourself familiar with the LP_XMLConverter (get's shipped with Archicad). The most interesting option is to invoke it to convert to the HSF format:

LP_XMLConverter libpart2hsf <source> <dest>

Always init your vars

All used variables in GDL must be initialized. (It still works if you don't most of the time, but Archicad will yell at you nonetheless)
A good way to init your arrays is to use a for loop.
This holds true especially for Strings. Basically GDL only knows two basic types, those are: Number, and String. Booleans are Numbers internally, too.
Every new variable used is pre-initialized as a number. You will get type errors if you set a new string var inside a subroutine and try to use it in the main script later.

All Relevant Stories correctly set up

!' Param script '!
ac_bottomlevel = GLOB_HSTORY_ELEV   GLOB_ELEVATION
ac_toplevel = ac_bottomlevel   ZZYZX
parameters  ac_bottomlevel = ac_bottomlevel,
            ac_toplevel = ac_toplevel

Font selection

To automagically get a proper font selection make a new string parameter and name it fontType. (There are a lot of similar parameters, that get a font selection. They are defined with others inside the ARCHICAD_LIBRARY_MASTER.gsm; Location in German lib: LCF > 4. Macros > Main XX : Base Macros XX)

But what if you need to specify multiple font faces in different places and want to have a drop-down selection list ready?
Do the following in the parameter script (with myFontFace being a string parameter):

!' param script !
dim fontNames[]
rrr = request("Fontnames_List", "", fontNames)
values "myFontFace" fontNames, CUSTOM

Pretty sure you have observed, that this system-generated font list will include fonts starting with the "@" sign ("at"-sign). Those fonts are used in vertical CJK context and shouldn't really be applied. At least outside of Asia those fonts are useless. For more info see here.
A solution is to just pass the list through a loop sorting out fonts with an "@" in their name:

!' still param script !
dim reducedFontNames[]
k = 0
for i = 1 to vardim1(fontNames)
	if not(strstr(fontNames[i], "@")) then
		k = k   1
		reducedFontNames[k] = fontNames[i]
	endif
next i

Passing variables

You can't pass parameters or arguments to subroutines. Instead you have to fall back to something I call "nasty caller":

if x = y then
	nasty_caller = 1
else
	nasty_caller = 2
endif
gosub "mysubroutine"
END !'----------------------------!

"mysubroutine":
	i = foo * nasty_caller
	! (...)
return

You can however pass parameters when you are calling a macro. And there is even a second way: Macros are running in the same GDL context as the object from which the macro got called. This means you have access to the stack and you can pass information around this way, too. But beware, since you operating on the same stack and not a copy you could easily mess up!

UI_Infield over an image

How to put an INFIELD over an UI_PICT in User Interface?:
You have to write the UI_INFIELD twice into your UI script: once before and once after the UI_PICT command.

Precision

Due to the nature of floating point math comparing 2 real numbers might not yield the result you think. if real_a = real_b … and therelike will result in the GDL editor yelling at you. To circumvent any errors you should rather subtract the two values and check if the result falls short of a specified machine epsilon, mostly abbreviated as eps in GDL code. A very detailed structure could look like this:

dict EPS
EPS.length	= 0.0001				!' 1/10 mm
EPS.square	= EPS.length**2
EPS.scalar	= EPS.square
EPS.angle	= acs(1 - EPS.scalar)	!' 0.0081°

Determining if two numbers are the same would look like this now:

if (real_a - real_b) < EPS.length then [...] 

Reno Status

To get the renovation status of the object use APPLICATON_QUERY:

n = application_query("OwnCustomParameters", "GetParameter(Renovation.RenovationStatus)", parValue)

parValue will hold the reno status as localised(!) string.
This script will display all the built-in properties as text in the 2D. Source

All Built-in Properties
The whole list:  
! built-in properties
"Builtin.Design_Option_Name"
"Builtin.Design_Option_ID"
"Builtin.Design_Option_Set_Name"
"Builtin.General_Area"
"Builtin.General_Height"
"Builtin.General_NetVolume"
"Builtin.General_Width"
"Builtin.General_ElevationToProjectZero"
"Builtin.General_ElevationToFirstReferenceLevel"
"Builtin.General_ElevationToSecondReferenceLevel"
"Builtin.General_ElevationToSeaLevel"
"Builtin.General_ElevationToStory"
"Builtin.General_HomeOffset"
"Builtin.General_TopOffset"
"Builtin.General_SurfaceArea"
"Builtin.General_3DLength"
"Builtin.General_Thickness"
"Builtin.General_ConditionalVolume"
"Builtin.General_GrossVolume"
"Builtin.General_InsulationSkinThickness"
"Builtin.General_3DPerimeter"
"Builtin.General_FloorPlanPerimeter"
"Builtin.General_Holes3DPerimeter"
"Builtin.General_FloorPlanHolesPerimeter"
"Builtin.General_SlantAngle"
"Builtin.General_TopElevationToFirstReferenceLevel"
"Builtin.General_TopElevationToHomeStory"
"Builtin.General_TopElevationToProjectZero"
"Builtin.General_TopElevationToSeaLevel"
"Builtin.General_TopElevationToSecondReferenceLevel"
"Builtin.General_BottomElevationToFirstReferenceLevel"
"Builtin.General_BottomElevationToHomeStory"
"Builtin.General_BottomElevationToProjectZero"
"Builtin.General_BottomElevationToSecondReferenceLevel"
"Builtin.General_BottomElevationToSeaLevel"
"Builtin.General_OpeningNumber"
"Builtin.General_CrossSectionHeightAtEndPerpendicular"
"Builtin.General_CrossSectionHeightAtBeginPerpendicular"
"Builtin.General_CrossSectionWidthAtEndPerpendicular"
"Builtin.General_CrossSectionWidthAtBeginPerpendicular"
"Builtin.General_CrossSectionHeightAtEndCut"
"Builtin.General_CrossSectionHeightAtBeginCut"
"Builtin.General_CrossSectionWidthAtEndCut"
"Builtin.General_CrossSectionWidthAtBeginCut"
"Builtin.General_CrossSectionAreaAtBeginCut"
"Builtin.General_CrossSectionAreaAtEndCut"
"Builtin.Component_NetProjectedArea"
"Builtin.Component_Thickness"
"Builtin.Component_CrossSectionHeight"
"Builtin.Component_CrossSectionWidth"
"Builtin.Component_CrossSectionArea"
"Builtin.Component_NetVolume"
"Builtin.Component_GrossVolume"
"Builtin.Component_GrossProjectedArea"
"Builtin.Component_ConditionalProjectedArea"
"Builtin.Component_ConditionalVolume"

Advanced

Label Placing

Place a label there, where the user has actually clicked (having no marker):

if not(LABEL_HAS_POINTER) then
	add2  LABEL_POSITION [2][1]	  LABEL_POSITION [3][1],
		  LABEL_POSITION [2][2]	  LABEL_POSITION [3][2]
endif

[source]


Changes

Random experiences with changes in GDL.

AC 24

While Archicad 24 did not bring any new GDL commands or functions, the HSF compared to 23 still slightly changed. Inside the libpartdocs.xml file the copyright node lost its additional it hold before: <Copyright SectVersion="1" SectionFlags="0" SubIdent="0"> is now just <Copyright>.


See also selfGDL