Jump to content

Calcium looping

From Wikipedia, the free encyclopedia

Calcium looping (CaL), or the regenerative calcium cycle (RCC), is a second-generation carbon capture technology.[1] It is the most developed form of carbonate looping, where a metal (M) is reversibly reacted between its carbonate form (MCO3) and its oxide form (MO) to separate carbon dioxide from other gases coming from either power generation or an industrial plant. In the calcium looping process, the two species are calcium carbonate (CaCO3) and calcium oxide (CaO). The captured carbon dioxide can then be transported to a storage site, used in enhanced oil recovery or used as a chemical feedstock. Calcium oxide is often referred to as the sorbent.

Calcium looping is being developed as it is a more efficient, less toxic alternative to current post-combustion capture processes such as amine scrubbing.[2] It also has interesting potential for integration with the cement industry.[3][4]

Basic concept

[edit]
CaCO3 ←→ CaO CO2 ΔH = 178 kJ/mol 1

There are two main steps in CaL:[5]

  • Calcination: Solid calcium carbonate is fed into a calciner, where it is heated to 850-950 °C to cause it to thermally decompose into gaseous carbon dioxide and solid calcium oxide (CaO). The almost-pure stream of CO2 is then removed and purified so that it is suitable for storage or use. This is the 'forward' reaction in the equation above.
  • Carbonation: The solid CaO is removed from the calciner and fed into the carbonator. It is cooled to approximately 650 °C and is brought into contact with a flue gas containing a low to medium concentration of CO2. The CaO and CO2 react to form CaCO3, thus reducing the CO2 concentration in the flue gas to a level suitable for emission to the atmosphere. This is the 'backward' reaction in the equation above.

Note that carbonation is calcination in reverse.

Whilst the process can be theoretically performed an infinite number of times, the calcium oxide sorbent degrades as it is cycled.[5] For this reason, it is necessary to remove (purge) some of the sorbent from the system and replace it with fresh sorbent (often in the carbonate form). The size of the purge stream compared with the amount of sorbent going round the cycle affects the process considerably.[6]

Background

[edit]

In the Ca-looping process, a CaO-based sorbent, typically derived from limestone, reacts via the reversible reaction described in Equation (1) and is repeatedly cycled between two vessels.

The forward, endothermic step is called calcination while the backward, exothermic step is carbonation.

A typical Ca-looping process for post-combustion CO2 capture is shown in Figure 1, followed by a more detailed description.

Flue gas containing CO2 is fed to the first vessel (the carbonator), where carbonation occurs. The CaCO3 formed is passed to another vessel (the calciner). Calcination occurs at this stage, and the regenerated CaO is quickly passed back to the carbonator, leaving a pure CO2 stream behind. As this cycle continues, CaO sorbent is constantly replaced by fresh (reactive) sorbent.[7] The highly concentrated CO2 from the calciner is suitable for sequestration, and the spent CaO has potential uses elsewhere, most notably in the cement industry. The heat necessary for calcination can be provided by oxy-combustion of coal below.

Oxy-combustion of coal: Pure oxygen rather than air is used for combustion, eliminating the large amount of nitrogen in the flue-gas stream. After particulate matter is removed, flue gas consists only of water vapor and CO2, plus smaller amounts of other pollutants. After compression of the flue gas to remove water vapor and additional removal of air pollutants, a nearly pure CO2 stream suitable for storage is produced.

The carbonator's operating temperature of 650-700 °C is chosen as a compromise between higher equilibrium (maximum) capture at lower temperatures due to the exothermic nature of the carbonation step, and a decreased reaction rate. Similarly, the temperature of >850 °C in the calcinator strikes a balance between increased rate of calcination at higher temperatures and reduced rate of degradation of CaO sorbent at lower temperatures.

Process description

[edit]

CaL is usually designed using a dual fluidised bed system to ensure sufficient contact between the gas streams and the sorbent.[5][8][9][10][11][12][13] The calciner and carbonator are fluidised beds with associated process equipment for separating the gases and solids attached (such as cyclones). Calcination is an endothermic process and as such requires the application of heat to the calciner. The opposite reaction, carbonation, is exothermic and heat must be removed. Since the exothermic reaction happens at about 650 °C and the endothermic reaction at 850-950 °C, the heat from the carbonator cannot be directly used to heat the calciner.

The fluidisation of the solid bed in the carbonator is achieved by passing the flue gas through the bed. In the calciner, some of the recovered CO2 is recycled through the system.[5] Some oxygen may also be passed through the reactor if fuel is being burned in the calciner to provide energy.

Provision of energy to the calciner

[edit]

Heat can be provided for the endothermic calcination step either directly or indirectly.

Direct provision of heat involves the combustion of fuel in the calciner itself (fluidised bed combustion). This is generally assumed to be done under oxy-fuel conditions; i.e. oxygen rather than air is used to burn the fuel to prevent dilution of the CO2 with nitrogen. The provision of oxygen for the combustion uses much electricity and is associated with high investment costs.[14] Other air separation processes are being developed.[15]

The penalties of calcium looping may be reduced by providing the heat for the calcination indirectly. This can be done in one of the following ways:

  • Combustion of fuel in an external chamber and conduction of energy in to the vessel[16]
  • Combustion of fuel in an external chamber and use of a heat transfer medium.[8]

Indirect methods are generally less efficient but do not require the provision of oxygen for combustion within the calciner to prevent dilution. The flue gas from the combustion of fuel in the indirect method could be mixed with the flue gas from the process that the CaL plant is attached to and passed through the carbonator to capture the CO2.

One efficient way of transferring heat into the calciner is by means of heat pipes.[17] The indirectly heated calcium looping (IHCaL) using heat pipes has high potential to decarbonize the lime and cement industry.[14][18] The deployment of this technology with refuse-derived fuels would allow to achieve net negative CO2 emissions.[19]

Recovery of energy from the carbonator

[edit]

Although the heat from the carbonator is not at a high enough temperature to be used in the calciner, the high temperatures involved (>600 °C) mean that a relatively efficient Rankine cycle for generating electricity can be operated.[20]

Note that the waste heat from the market-leading amine scrubbing CO2 capture process is emitted at a maximum of 150 °C.[15] The low temperature of this heat means that it contains much less exergy and can generate much less electricity through a Rankine or organic Rankine cycle.

This electricity generation is one of the main benefits of CaL over lower-temperature post-combustion capture processes as the electricity is an extra revenue stream (or reduces costs).

Sorbent degradation

[edit]

It has been shown that the activity of the sorbent reduces quite markedly in laboratory, bench-scale and pilot plant tests. This degradation has been attributed to three main mechanisms, as shown below.[5]

Attrition

[edit]

Calcium oxide is friable, that is, quite brittle. In fluidised beds, the calcium oxide particles can break apart upon collision with the other particles in the fluidised bed or the vessel containing it.[9][10] The problem seems to be greater in pilot plant tests[21] than at a bench scale.

Sulfation

[edit]

Sulfation is a relatively slow reaction (several hours) compared with carbonation (<10 minutes); thus it is more likely that SO2 will come into contact with CaCO3 than CaO. However, both reactions are possible, and are shown below.

Indirect sulfation: CaO SO2 1/2 O2 → CaSO4
Direct sulfation: CaCO3 SO2 1/2 O2 → CaSO4 CO2

Because calcium sulfate has a greater molar volume than either CaO or CaCO3 a sulfated layer will form on the outside of the particle, which can prevent the uptake of CO2 by the CaO further inside the particle.[5] Furthermore, the temperature at which calcium sulfate dissociates to CaO and SO2 is relatively high, precluding sulfation's reversibility at the conditions present in CaL.

Technical implications

[edit]

Calcium looping technology offers several technical advantages over amine scrubbing for carbon capture. Firstly, both carbonator and calciner can use fluidized bed technology, due to the good gas-solid contacting and uniform bed temperature. Fluidized bed technology has already been demonstrated at large scale: large (460MWe) atmospheric and pressurized systems exist, and there is not a need for intensive scaling up as there is for the solvent scrubbing towers used in amine scrubbing.[22]

Also, the calcium looping process is energy efficient. The heat required for the endothermic calcination of CaCO3 and the heat required to raise the temperature of fresh limestone from ambient temperature, can be provided by in-situ oxy-fired combustion of fuel in the calciner. Although additional energy is required to separate O2 from N2, the majority of the energy input can be recovered because the carbonator reaction is exothermic and CO2 from the calciner can be used to power a steam cycle. A solid purge heat exchanger can also be utilized to recover energy from the deactivated CaO and coal ashes from the calciner.[23] As a result, a relatively small efficiency penalty is imposed on the power process, where the efficiency penalty refers to the power losses for CO2 compression, air separation and steam generation.[24] It is estimated at 6-8 % points, compared to 9.5-12.5 % from post combustion amine capture.[25]

The main shortcoming of Ca-looping technology is the decreased reactivity of CaO through multiple calcination-carbonation cycles. This can be attributed to sintering and the permanent closure of small pores during carbonation.

Closure of small pores

[edit]

The carbonation step is characterized by a fast initial reaction rate abruptly followed by a slow reaction rate (Figure 2). The carrying capacity of the sorbent is defined as the number of moles of CO2 reacted in the period of fast reaction rate with respect to that of the reaction stoichiometry for complete conversion of CaO to CaCO3. As seen in Figure 2, while mass after calcination remains constant, the mass change upon carbonation- the carrying capacity- reduces with a large number of cycles. In calcination, porous CaO (molar volume = 16.9 cm3/g) is formed in place of CaCO3 (36.9 cm3/g.). On the other hand, in carbonation, the CaCO3 formed on the surface of a CaO particle occupies a larger molar volume. As a result, once a layer of carbonate has formed on the surface (including on the large internal surface of porous CaO), it impedes further CO2 capture. This product layer grows over the pores and seals them off, forcing carbonation to follow a slower, diffusion dependent mechanism.

Sintering

[edit]

CaO is also prone to sintering, or change in pore shape, shrinkage and grain growth during heating.[26] Ionic compounds such as CaO mostly sinter because of volume diffusion or lattice diffusion mechanics. As described by sintering theory,[27] vacancies generated by temperature sensitive defects direct void sites from smaller to larger ones, explaining the observed growth of large pores and the shrinkage of small pores in cycled limestone.[28] It was found that sintering of CaO increases at higher temperatures and longer calcination durations, whereas carbonation time has minimal effect on particle sintering. A sharp increase in sintering of particles is observed at temperatures above 1173 K,[29] causing a reduction in reactive surface area and a corresponding decrease in reactivity.

Solutions: Several options to reduce sorbent deactivation are currently being researched. An ideal sorbent would be mechanically strong, maintain its reactive surface through repeated cycles, and be reasonably inexpensive. Using thermally pre-activated particles or reactivating spent sorbents through hydration are two promising options. Thermally pre-activated particles have been found to retain activity for up to a thousand cycles. Similarly, particles reactivated by hydration show improved long term (after~20 cycles) conversions.[30]

Disposal of waste sorbent

[edit]

Properties of waste sorbent

[edit]

After cycling several times and being removed from the calcium loop, the waste sorbent will have attrited, sulfated and become mixed with the ash from any fuel used. The amount of ash in the waste sorbent will depend on the fraction of the sorbent being removed and the ash and calorific content of the fuel. The size fraction of the sorbent is dependent on the original size fraction but also the number of cycles used and the type of limestone used.[31]

Disposal routes

[edit]

Proposed disposal routes of waste sorbent include:

  • Landfill;
  • Disposal at sea;
  • Use in cement manufacture;
  • Use in flue gas desulfurisation (FGD).

The lifecycle CO2 emissions for power generation with CaL and the first three disposal techniques have been calculated.[32] Before disposal of the CaO coal power with CaL has a similar level of lifecycle emissions as amine scrubbing but with the CO2-absorbing properties of CaO CaL becomes significantly less polluting. Ocean disposal was found to be the best, but current laws relating to dumping waste at sea prevent this. Next best was use in cement manufacture, reducing emissions over an unabated coal plant by 93%.

Use in lime and cement manufacture

[edit]

The manufacture of lime and cement is responsible for approximately 8% of the world's CO2 emissions.[14] Around 65% of this CO2 comes from the calcination of calcium carbonate as shown earlier in this article, and the rest from fuel combustion. By replacing some or all of the calcium carbonate entering the plant with waste calcium oxide, the CO2 caused from calcination can be avoided, as well as some of the CO2 from fossil fuel combustion.

This calcium oxide could be sourced from other point sources of CO2 such as power stations, but most effort has been focussed on integrating calcium looping with Portland cement manufacture. By replacing the calciner in the cement plant with a calcium looping plant, it should be possible to capture 90% or more of the CO2 relatively inexpensively. There are alternative set-ups such as placing the calcium looping plant in the preheater section so as to make the plant as efficient as possible or to indirectly heat the calciner for increased energy efficiency.[19]

Some work has been undertaken into whether calcium looping affects the quality of the Portland cement produced, but results so far seem to suggest that the production of strength-giving phases such as alite are similar for calcium looped and non-calcium looped cement.[33]

Direct Separation Technology

[edit]

Calix Ltd has developed a new type of kiln that enables the CO2 from the calcination process to be driven off as a pure stream. Calix achieves this by calcining finely ground CaCO3 continuously down vertical reactor tubes. The reactor tubes are heated from the outside using electricity or fuel ensuring the CO2 stream is pure and not contaminated with air or combustion products.[34]

This technology has been successfully piloted in Europe by a cooperative industry group with support from the European Union as the Low Emission Intensity Lime And Cement (LEILAC1) reactor project. The study report concluded that the technology could capture C02 from full scale lime and cement kilns at €14 to €24/t.[35] Transport and storage costs are not included in this estimate and will be dependent upon infrastructure available near the cement or lime plant

A FEED study is underway for a larger commercial demonstration kiln proposed for the Heidelberg Cement plant in Hannover (LEILAC2). This commercial demonstration kiln is designed to capture 100ktpa CO2.[36] Leilac-2 passed its Financial Investment Decision (FID) in March 2022, and it's Front End Engineering Design (FEED) Study Summary was completed and published on 13 October 2023, leading to a new and improved design and revised timeline. The next milestone is procurement of long lead items, currently underway (2023).[37]

This type of kiln is also being studied as a potential method to decarbonise shipping through both looping and single use processes. The single use process would involve using CaCO3 to be sown over the ocean, thereby permanently capturing addition carbon from the ocean as the CaCO3 reacts to form Ca(HCO3)2 and reversing ocean acidification.[38]

Economic implications

[edit]

Calcium looping has several economic advantages.

Cost per metric ton for CO2 captured

[edit]

Firstly, Ca-looping offers greater cost advantage compared to conventional amine-scrubbing technologies. The cost/metric ton for CO2 captured through Ca-looping is ~$23.70 whereas that for CO2 captured through amine scrubbing is about $35–$96.[39] This can be attributed to the high availability and low cost of the CaO sorbent (derived from limestone) as compared to MEA. Also, Ca-looping imposes a lower energy penalty than amine scrubbing, resulting in lower energy costs. The amine scrubbing process is energy intensive, with approximately 67% of the operating costs going into steam requirements for solvent regeneration. A more detailed comparison of Ca-looping and amine scrubbing is shown below.

Comparison of Ca-looping and Amine Scrubbing
Amine Scrubbing Ca-Looping
Cost/CO2 avoided ~ $35–96/ton ~$23.70/ ton
Raw material cost[40] $1,250/ton MEA $25/ton CaCO3
Efficiency Penalty 6-12% 6-8%

Cost of CO2 emissions avoided through Ca-looping

[edit]

In addition, the cost of CO2 emissions avoided through Ca-looping is lower than the cost of emissions avoided via an oxyfuel combustion process (~US$23.8/t). This can be explained by the fact that, despite the capital costs incurred in constructing the carbonator for Ca-looping, CO2 will not only be captured from the oxy-fired combustion, but also from the main combustor (before the carbonator). The oxygen required in the calciners is only 1/3 that required for an oxyfuel process, lowering air separation unit capital costs and operating costs.[22] Sensitivity Analysis: Figure 3 shows how varying 8 separate parameters affects the cost/metric ton of CO2 captured through Ca-looping. It is evident that the dominant variables that affect cost are related to sorbent use, the Ca/C ratio and the CaO deactivation ratio. This is because the large sorbent quantities required dominate the economics of the capture process. Low costs of CO2 avoided for the indirectly heated Ca-looping process have been reported for integrated concepts in the lime production.[14]

These variables should therefore be taken into account to achieve further cost reductions in the Ca-looping process. The cost of limestone is largely driven by market forces, and is outside the control of the plant. Currently, carbonators require a Ca/C ratio of 4 for effective CO2 capture. However, if the Ca/C ratio or CaO deactivation is reduced (i.e. the sorbent can be made to work more efficiently), the reduction in material consumption and waste can lower feedstock demand and operating costs.

Cement production

[edit]

Finally, favorable economics can be achieved by using the purged material from the calcium looping cycle in cement production. The raw feed for cement production includes ~ 85 wt% limestone with the remaining material consisting of clay and additives (e.g. SiO2, Al2O3 etc.).[41] The first step in the process involves calcinating limestone to produce CaO, which is then mixed with other materials in a kiln to produce clinker.

Using purged material from a Ca-looping system would reduce the raw material costs for cement production. Waste CaO and ash can be used in place of CaCO3 (the main constituent cement feed). The ash could also fulfill the aluminosilicate requirements otherwise supplied by additives. Since over 60% of the energy used in cement production goes into heat input for the precalciner, this integration with Ca-looping and the consequent reduced need for a calcination step, could lead to substantial energy savings (EU, 2001). However, there are problems with using the waste CaO in cement manufacture. If the technology is applied on a large scale, the purge rate of CaO should be optimized to minimize waste.[42]

Political and environmental implications

[edit]

To fully gauge the viability of calcium looping as a capture process, it is necessary to consider the political, environmental, and health effects of the process as well.

Political implications

[edit]

Though many recent scientific reports (e.g.: the seven-wedge stabilization plan by Pacala and Socolow) convey an urgent need to deploy CCS, this urgency has not spread to the political establishment,[43] mainly due to the high costs and energy penalty of CCS [44] The economics of calcium looping are integral to its political viability. One economic and political advantage is the ability for Ca-looping to be retrofitted onto existing power plants, rather than requiring new plants to be built. The IEA sees power plants as an important target for carbon capture, and has set the goal to have all fossil fuel based power plants deploy CCS systems by 2040.[45] However, power plants are expensive to build, and long lived. Retrofitting of post-combustion capture systems, such as Ca-looping, seems to be the only politically and economically viable way to achieve the IEA's goal.

A further political advantage is the potential synergy between calcium looping and cement production. An IEA report concludes that to meet emission reduction goals, there should be 450 CCS projects in India and China by 2050.[45] However, this could be politically difficult, especially with these nations' numerous other development goals. After all, for a politician to commit money to CCS might be less advantageous than to commit it to job schemes or agricultural subsidies. Here, the integration of calcium looping with the prosperous and (particularly with infrastructure expansion in the developing world) vital cement industry might prove compelling to the political establishment.

This potential synergy with the cement industry also provides environmental benefits by simultaneously reducing the waste output of the looping process and decarbonizing cement production. Cement manufacture is energy and resource intensive, consuming 1.5 tonnes of material per tonne of cement produced.[46] In the developing world, economic growth will drive infrastructure growth, increasing cement demand. Deploying a waste product for cement production could therefore have a large, positive environmental impact.

Environmental implications

[edit]

The starting material for calcium looping is limestone, which is environmentally benign and widely available, accounting for over 10% (by volume) of all sedimentary rock. Limestone is already mined and cheaply obtainable. The mining process has no major known adverse environmental effects, beyond the unavoidable intrusiveness of any mining operation. However, as the following calculation shows, despite integration with cement industry, waste from Ca-looping can still be a problem.

From the environmental and health standpoint, Ca-looping compares favorably with amine scrubbing. Amine scrubbing is known to generate air pollutants, including amines and ammonia, which can react to form carcinogenic nitrosamines.[47] Calcium looping, on the other hand, does not produce harmful pollutants. In addition, not only does it capture CO2, but it also removes the pollutant SO2 from the flue gas.[48] This is both an advantage and disadvantage, as the air quality improves, but the captured SO2 has a detrimental effect on the cement that is generated from the calcium looping wastes.

Advantages and drawbacks

[edit]

Advantages of the process

[edit]

Calcium looping is considered as potential promising solutions to reduce CO2 capture energy penalty.[49] There are many advantages from the calcium looping methods. Firstly, the method has been proved to yield a low efficiency penalties (5-8% points) while other mature CO2 capture systems yield a higher efficiency penalties (8–12.5%).[50] Moreover, the method is well suited for a wide range of flue gases. Calcium looping is applicable for new builds and retrofits to existing power stations or other stationary industrial CO2 sources because the method can be implemented using large-scale circulating fluidized beds while other methods such as amine scrubbing is required a vastly upscale solvent scrubbing towers.[51] In addition, crushed limestone used in calcium looping as the sorbent is a natural product, which is well distributed all over the world, non-hazardous and inexpensive. Many cement manufacturers or power plants located close to limestone sources could conceivably employ Calcium looping for CO2 capture. The waste sorbent can be used in cement manufacture.

Drawbacks

[edit]

Apart from these advantages, there are several disadvantages needed to take into considerations. The plant integrating Ca-Looping might require a high construction investment because of the high thermal power of the post-combustion calcium loop. The sorbent capacity decreases significantly with the number of cycles for every carbonation-calcination cycle so the calcium-looping unit will require a constant flow of limestone. In order to increase the long-term reactivity of the sorbent or to reactivate the sorbent, some methods are under investigation such as thermal pretreatment, chemical doping and the production of artificial sorbents.[51] The method applying the concept of fluidized bed reactor, but there are some problems causing the uncertainty for the process. Attrition of the limestone can be a problem during repeated cycling.[25]

Benefits of calcium looping compared with other post-combustion capture processes

[edit]

Calcium looping compares favorably with several post-combustion capture technologies. Amine scrubbing is the capture technology closest to being market-ready, and calcium looping has several marked benefits over it. When modeled on a 580 MW coal-fired power plant, Calcium looping experienced not only a smaller efficiency penalty (6.7-7.9% points compared to 9.5% for monoethanolamine and 9% for chilled ammonia) but also a less complex retrofitting process. Both technologies would require the plant to be retrofitted for adoption, but the calcium looping retrofitting process would result in twice the net power output of the scrubbing technology.[52] Furthermore, this advantage can be compounded by introducing technology such as cryogenic O2 separation systems. This ups the efficiency of the calcium looping technology by increasing the energy density by 57.4%, making the already low energy penalties even less of an issue.[53]

Calcium looping already has an energy advantage over amine scrubbing, but the main problem is that amine scrubbing is the more market-ready technology. However, the accompanying infrastructure for amine scrubbing include large solvent scrubbing towers, the likes of which have never been used on an industrial scale.[25] The accompanying infrastructure for calcium looping capture technologies are circulating fluidized beds, which have already been implemented on an industrial scale. Although the individual technologies differ in terms of current technological viability, the fact that the infrastructure needed to properly implement an amine scrubbing system has yet to be developed keeps calcium looping competitive from a viability standpoint.

Sample evaluation

[edit]

Assumptions

[edit]
  1. For a Ca-looping cycle installed on a 500 MW power plant, the purge rate is 12.6 kg CaO/s.[7]
  2. For the cement production process, 0.65 kg CaO is required/ kg cement produced.[7]
  3. U.S. electric generation capacity (only fossil fuels): Natural gas = 415 GW, Coal= 318 GW & Petroleum = 51 GW [54]
  4. Cement consumption in U.S. = 110,470 × 103 metric tons = 1.10470 × 108 metric tons = 1.10470 × 1011 kg.[55]

Calculations

[edit]

For a single Ca-looping cycle installed on a 500MW power plant:

  1. Amount of CaO from purge annually = 12.6 kg CaO/s × 365 days/year × 24 hr/day × 3600s / hour = 3.97 × 108 kg CaO/ year
  2. Cement that can be obtained from purge annually= 3.97 × 108 kg CaO/ year × 1 kg cement/ 0.65 kg CaO = 6.11 × 108 kg cement/year
  3. Net electricity generation in US: (415 318 51) GW = 784 GW = 7.84 × 1011 W
  4. Number of 500 MW power plants: 7.84 × 1011 W / 5.00 × 108 W = 1568 power plants
  5. Amount of cement that can be produced from Ca-looping waste: 1568 × 6.11 × 108 kg cement/ year = 9.58 × 1011 kg cement/year
  6. Production from Ca-looping waste as percent of total annual cement consumption = [(9.58 × 1011 kg)/ (1.10470 × 1011 kg)] × 100 = 870%

Therefore, amount of cement production from Ca-looping waste of all fossil fuel based electric power plants in US will be far greater than net consumption. To make Ca-looping more viable, waste must be minimized (i.e. sorbent degradation reduced) to ideally about 1/10th of current levels.

References

[edit]
  1. ^ Plaza, Marta G.; Martínez, Sergio; Rubiera, Fernando (October 2020). "CO2 Capture, Use, and Storage in the Cement Industry: State of the Art and Expectations". Energies. 13 (21): 5692. doi:10.3390/en13215692. hdl:10261/229057. ISSN 1996-1073.
  2. ^ Ahn, Hyungwoong; Luberti, Mauro; Liu, Zhengyi; Brandani, Stefano (August 2013). "Process configuration studies of the amine capture process for coal-fired power plants" (PDF). International Journal of Greenhouse Gas Control. 16: 29–40. Bibcode:2013IJGGC..16...29A. doi:10.1016/j.ijggc.2013.03.002. hdl:20.500.11820/71612863-b15f-47d4-82e9-394690da5164.
  3. ^ Dean, C.C.; Blamey, J.; Florin, N.H.; Al-Jeboori, M.J.; Fennell, P.S. (June 2011). "The calcium looping cycle for CO2 capture from power generation, cement manufacture and hydrogen production" (PDF). Chemical Engineering Research and Design. 89 (6): 836–855. doi:10.1016/j.cherd.2010.10.013. hdl:10044/1/12266.2 capture from power generation, cement manufacture and hydrogen production&rft.volume=89&rft.issue=6&rft.pages=836-855&rft.date=2011-06&rft_id=info:hdl/10044/1/12266&rft_id=info:doi/10.1016/j.cherd.2010.10.013&rft.aulast=Dean&rft.aufirst=C.C.&rft.au=Blamey, J.&rft.au=Florin, N.H.&rft.au=Al-Jeboori, M.J.&rft.au=Fennell, P.S.&rft_id=http://spiral.imperial.ac.uk/bitstream/10044/1/12266/6/MANUSCRIPT%20accepted%20CHERD-2.pdf&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  4. ^ Dean, Charles C.; Dugwell, Denis; Fennell, Paul S. (2011). "Investigation into potential synergy between power generation, cement manufacture and CO2 abatement using the calcium looping cycle". Energy & Environmental Science. 4 (6): 2050. doi:10.1039/C1EE01282G.2 abatement using the calcium looping cycle&rft.volume=4&rft.issue=6&rft.pages=2050&rft.date=2011&rft_id=info:doi/10.1039/C1EE01282G&rft.aulast=Dean&rft.aufirst=Charles C.&rft.au=Dugwell, Denis&rft.au=Fennell, Paul S.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  5. ^ a b c d e f Blamey, J.; Anthony, E.J.; Wang, J.; Fennell, P.S. (April 2010). "The calcium looping cycle for large-scale CO2 capture". Progress in Energy and Combustion Science. 36 (2): 260–279. doi:10.1016/j.pecs.2009.10.001.2 capture&rft.volume=36&rft.issue=2&rft.pages=260-279&rft.date=2010-04&rft_id=info:doi/10.1016/j.pecs.2009.10.001&rft.aulast=Blamey&rft.aufirst=J.&rft.au=Anthony, E.J.&rft.au=Wang, J.&rft.au=Fennell, P.S.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  6. ^ Rodriguez, N.; Alonso, M.; Grasa, G.; Abanades, J. Carlos (May 2008). "Heat requirements in a calciner of CaCO3 integrated in a CO2 capture system using CaO". Chemical Engineering Journal. 138 (1–3): 148–154. Bibcode:2008ChEnJ.138..148R. doi:10.1016/j.cej.2007.06.005. hdl:10261/11449.
  7. ^ a b c Blamey, J.; Anthony, E.J.; Wang, J.; Fennell, P.S. 2010, The Calcium Looping Cycle for large-scale CO2 capture. Progress in Energy and Combustion Science vol. 36 (2) p. 260-279
  8. ^ a b Rodríguez, N.; Alonso, M.; Grasa, G.; Abanades, J. Carlos (15 September 2008). "Process for Capturing CO2 Arising from the Calcination of the CaCO3 Used in Cement Manufacture". Environmental Science & Technology. 42 (18): 6980–6984. Bibcode:2008EnST...42.6980R. doi:10.1021/es800507c. PMID 18853819.
  9. ^ a b Kim, Jun Young; Ellis, Naoko; Lim, C.Jim; Grace, John R. (2020). "Effect of calcination/carbonation and oxidation/reduction on attrition of binary solid species in sorption-enhanced chemical looping reforming". Fuel. 271: 117665. Bibcode:2020Fuel..27117665K. doi:10.1016/j.fuel.2020.117665. ISSN 0016-2361. S2CID 216449129.
  10. ^ a b Kim, Jun Young; Ellis, Naoko; Lim, C.Jim; Grace, John R. (2020). "Attrition of binary mixtures of solids in a jet attrition unit". Powder Technology. 352: 445–452. doi:10.1016/j.powtec.2019.05.010. ISSN 0032-5910. S2CID 164585879.
  11. ^ Shimizu, T.; Hirama, T.; Hosoda, H.; Kitano, K.; Inagaki, M.; Tejima, K. (January 1999). "A Twin Fluid-Bed Reactor for Removal of CO2 from Combustion Processes". Chemical Engineering Research and Design. 77 (1): 62–68. doi:10.1205/026387699525882.2 from Combustion Processes&rft.volume=77&rft.issue=1&rft.pages=62-68&rft.date=1999-01&rft_id=info:doi/10.1205/026387699525882&rft.aulast=Shimizu&rft.aufirst=T.&rft.au=Hirama, T.&rft.au=Hosoda, H.&rft.au=Kitano, K.&rft.au=Inagaki, M.&rft.au=Tejima, K.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  12. ^ Fennell, Paul S.; Pacciani, Roberta; Dennis, John S.; Davidson, John F.; Hayhurst, Allan N. (July 2007). "The Effects of Repeated Cycles of Calcination and Carbonation on a Variety of Different Limestones, as Measured in a Hot Fluidized Bed of Sand". Energy & Fuels. 21 (4): 2072–2081. doi:10.1021/ef060506o.
  13. ^ Florin, Nicholas H.; Blamey, John; Fennell, Paul S. (19 August 2010). "Synthetic CaO-Based Sorbent for CO2 Capture from Large-Point Sources". Energy & Fuels. 24 (8): 4598–4604. doi:10.1021/ef100447c.2 Capture from Large-Point Sources&rft.volume=24&rft.issue=8&rft.pages=4598-4604&rft.date=2010-08-19&rft_id=info:doi/10.1021/ef100447c&rft.aulast=Florin&rft.aufirst=Nicholas H.&rft.au=Blamey, John&rft.au=Fennell, Paul S.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  14. ^ a b c d Greco-Coppi, Martin; Seufert, Peter; Hofmann, Carina; Rolfe, Angela; Huang, Ye; Rezvani, Sina; Ströhle, Jochen; Epple, Bernd (2024). "Efficient CO2 capture from lime plants: Techno-economic assessment of integrated concepts using indirectly heated carbonate looping technology". Carbon Capture Science & Technology. 11: 100187. doi:10.1016/j.ccst.2023.100187. ISSN 2772-6568.
  15. ^ a b Boot-Handford, Matthew E.; Abanades, Juan C.; Anthony, Edward J.; Blunt, Martin J.; Brandani, Stefano; Mac Dowell, Niall; Fernández, José R.; Ferrari, Maria-Chiara; Gross, Robert; Hallett, Jason P.; Haszeldine, R. Stuart; Heptonstall, Philip; Lyngfelt, Anders; Makuch, Zen; Mangano, Enzo; Porter, Richard T. J.; Pourkashanian, Mohamed; Rochelle, Gary T.; Shah, Nilay; Yao, Joseph G.; Fennell, Paul S. (2014). "Carbon capture and storage update". Energy & Environmental Science. 7 (1): 130–189. doi:10.1039/C3EE42350F.
  16. ^ "Catalytic Flash Calcination (CFC) Technology". Calix Limited. Retrieved 21 March 2014.
  17. ^ Hoeftberger, Daniel; Karl, Juergen (2016-07-01). "The Indirectly Heated Carbonate Looping Process for CO2 Capture—A Concept With Heat Pipe Heat Exchanger". Journal of Energy Resources Technology. 138 (4). doi:10.1115/1.4033302. ISSN 0195-0738.
  18. ^ Greco-Coppi, Martin; Hofmann, Carina; Ströhle, Jochen; Walter, Diethelm; Epple, Bernd (2021). "Efficient CO2 capture from lime production by an indirectly heated carbonate looping process". International Journal of Greenhouse Gas Control. 112: 103430. doi:10.1016/j.ijggc.2021.103430. ISSN 1750-5836.
  19. ^ a b Greco-Coppi, Martin; Hofmann, Carina; Walter, Diethelm; Ströhle, Jochen; Epple, Bernd (2023-06-12). "Negative CO2 emissions in the lime production using an indirectly heated carbonate looping process". Mitigation and Adaptation Strategies for Global Change. 28 (6): 30. Bibcode:2023MASGC..28...30G. doi:10.1007/s11027-023-10064-7. ISSN 1573-1596.
  20. ^ Romeo, Luis M.; Abanades, J. Carlos; Escosa, Jesús M.; Paño, Jara; Giménez, Antonio; Sánchez-Biezma, Andrés; Ballesteros, Juan C. (October 2008). "Oxyfuel carbonation/calcination cycle for low cost CO2 capture in existing power plants". Energy Conversion and Management. 49 (10): 2809–2814. doi:10.1016/j.enconman.2008.03.022.2 capture in existing power plants&rft.volume=49&rft.issue=10&rft.pages=2809-2814&rft.date=2008-10&rft_id=info:doi/10.1016/j.enconman.2008.03.022&rft.aulast=Romeo&rft.aufirst=Luis M.&rft.au=Abanades, J. Carlos&rft.au=Escosa, Jesús M.&rft.au=Paño, Jara&rft.au=Giménez, Antonio&rft.au=Sánchez-Biezma, Andrés&rft.au=Ballesteros, Juan C.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  21. ^ Lu, Dennis Y.; Hughes, Robin W.; Anthony, Edward J. (December 2008). "Ca-based sorbent looping combustion for CO2 capture in pilot-scale dual fluidized beds". Fuel Processing Technology. 89 (12): 1386–1395. doi:10.1016/j.fuproc.2008.06.011.2 capture in pilot-scale dual fluidized beds&rft.volume=89&rft.issue=12&rft.pages=1386-1395&rft.date=2008-12&rft_id=info:doi/10.1016/j.fuproc.2008.06.011&rft.aulast=Lu&rft.aufirst=Dennis Y.&rft.au=Hughes, Robin W.&rft.au=Anthony, Edward J.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  22. ^ a b Blamey, J.; Anthony, E.J.; Wang, J.; Fennell, P.S. (2010). "The Calcium Looping Cycle for large-scale CO2 capture". Progress in Energy and Combustion Science. 36 (2): 260–279. doi:10.1016/j.pecs.2009.10.001.
  23. ^ Romeo LM, Abanades JC, Escosa JM, Pano J, Giminez A, Sanchez-Biezma A, et al. Oxyfuel carbonation/calcination cycle for low cost CO2 capture in existing power plants. Energy Conversion and Management 2008;49(10):2809–14
  24. ^ Abanades, JC; Anthony, EJ; Wang, J; Oakey, JE (2005). "Fluidized bed combustion systems integrating CO2 capture with CaO". Environmental Science & Technology. 39 (8): 2861–6. Bibcode:2005EnST...39.2861A. doi:10.1021/es0496221. PMID 15884387.
  25. ^ a b c Blamey J., Anthony EJ, Wang J, Fennell PS, The calcium looping cycle for large-scale CO2 capture, Progress in Energy and Combustion Science 2010
  26. ^ Blamey J., Anthony EJ, Wang J, Fennell PS, "The calcium looping cycle for large-scale CO2 capture, Progress in Energy and Combustion Science 2010
  27. ^ German RM. Sintering Theory and Practice. New York: Wiley, 1996.
  28. ^ Sun, P; Grace, JR; Lim, CJ; Anthony, EJ (2007). "The effect of CaO sintering on cyclic CO2 capture in energy systems". AIChE Journal. 53 (9): 2432–42. Bibcode:2007AIChE..53.2432S. doi:10.1002/aic.11251.2 capture in energy systems&rft.volume=53&rft.issue=9&rft.pages=2432-42&rft.date=2007&rft_id=info:doi/10.1002/aic.11251&rft_id=info:bibcode/2007AIChE..53.2432S&rft.aulast=Sun&rft.aufirst=P&rft.au=Grace, JR&rft.au=Lim, CJ&rft.au=Anthony, EJ&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  29. ^ Borgwardt, RH (1989). "Sintering of nascent calcium oxide". Chemical Engineering Science. 44 (1): 53–60. Bibcode:1989ChEnS..44...53H. doi:10.1016/0009-2509(89)85232-7.
  30. ^ Manovic, V; Anthony, EJ (2008). "Thermal activation of CaO-based sorbent and self reactivation during CO2 capture looping cycles". Environmental Science & Technology. 42 (11): 4170–4. Bibcode:2008EnST...42.4170M. doi:10.1021/es800152s. PMID 18589983.2 capture looping cycles&rft.volume=42&rft.issue=11&rft.pages=4170-4&rft.date=2008&rft_id=info:pmid/18589983&rft_id=info:doi/10.1021/es800152s&rft_id=info:bibcode/2008EnST...42.4170M&rft.aulast=Manovic&rft.aufirst=V&rft.au=Anthony, EJ&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  31. ^ González, Belén (May 2010). Comportiamento de CaO Como Sorbente Regenerable para la Captura de CO2 (in Spanish). Spain: Universidad de Oviedo.2&rft.place=Spain&rft.pub=Universidad de Oviedo&rft.date=2010-05&rft.aulast=González&rft.aufirst=Belén&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  32. ^ Hurst, Thomas F.; Cockerill, Timothy T.; Florin, Nicholas H. (2012). "Life cycle greenhouse gas assessment of a coal-fired power station with calcium looping CO2 capture and offshore geological storage". Energy & Environmental Science. 5 (5): 7132. doi:10.1039/C2EE21204H.2 capture and offshore geological storage&rft.volume=5&rft.issue=5&rft.pages=7132&rft.date=2012&rft_id=info:doi/10.1039/C2EE21204H&rft.aulast=Hurst&rft.aufirst=Thomas F.&rft.au=Cockerill, Timothy T.&rft.au=Florin, Nicholas H.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  33. ^ Dean, Charles.; Hills, Thomas.; Florin, Nick.; Dugwell, Denis.; Fennell, Paul S. (2013). "Integrating Calcium Looping CO2 Capture with the Manufacture of Cement". Energy Procedia. 37: 7078–7090. doi:10.1016/j.egypro.2013.06.644. hdl:10453/116732.2 Capture with the Manufacture of Cement&rft.volume=37&rft.pages=7078-7090&rft.date=2013&rft_id=info:hdl/10453/116732&rft_id=info:doi/10.1016/j.egypro.2013.06.644&rft.aulast=Dean&rft.aufirst=Charles.&rft.au=Hills, Thomas.&rft.au=Florin, Nick.&rft.au=Dugwell, Denis.&rft.au=Fennell, Paul S.&rft_id=https://doi.org/10.1016%2Fj.egypro.2013.06.644&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  34. ^ "Our Technology - Innovating for the Earth". Calix | Agriculture, Wastewater, Infrastructure Solutions & More. Retrieved 2022-02-07.
  35. ^ "LEILAC Technology Roadmap to 2050". leilac. Retrieved 2022-02-07.
  36. ^ "LEILAC Publications | Front End Engineering and Design Summary Reports". leilac. Retrieved 2022-02-07.
  37. ^ "Project Leilac-2 - Capturing 100,000tpa of CO₂ Emissions". Leilac. Retrieved 2024-09-18.
  38. ^ "Windship Technology, Calix join forces to cut CO2 emissions". Offshore Energy. 2021-07-02. Retrieved 2022-02-07.
  39. ^ MacKenzie, A; Granatstein, DL; Anthony, EJ; Abanades, JC (2007). "Economics of CO2 capture using the calcium cycle with a pressurized fluidized bed combustion". Energy & Fuels. 21 (2): 920–6. doi:10.1021/ef0603378.2 capture using the calcium cycle with a pressurized fluidized bed combustion&rft.volume=21&rft.issue=2&rft.pages=920-6&rft.date=2007&rft_id=info:doi/10.1021/ef0603378&rft.aulast=MacKenzie&rft.aufirst=A&rft.au=Granatstein, DL&rft.au=Anthony, EJ&rft.au=Abanades, JC&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  40. ^ Rao and Rubin, 2002
  41. ^ Alsop, P. A., Chen, H., Tseng, H., 2007. The Cement Plant Operations Handbook, Fifth Edition, Tradeship Publications, Surrey, UK. Chapter 17.
  42. ^ MacKenzie, A; Granatstein, DL; Anthony, EJ; Abanades, JC (2007). "Economics of CO2 capture using the calcium cycle with a pressurized fluidized bed combustor". Energy & Fuels. 21 (2): 920–6. doi:10.1021/ef0603378.
  43. ^ Pacala S., Socolow R. Stabilizations Wedges: Solving the Climate Problem for the Next 50 Years with Current Technologies. Science, 2004. 305(5686), 968-972
  44. ^ Haszeldine R. Carbon Capture and Storage: How Green Can Black Be? Science, 2009. 325(8638), 1647-1652
  45. ^ a b IEA. Technology Roadmap: Carbon Capture and Storage. 2009
  46. ^ Jankovic, Alex. Walter Valery, Eugene Davis, "Cement grinding optimisation, Minerals Engineering, Volume 17, Issues 11–12, November–December 2004, Pages 1075-1081
  47. ^ Lag M., Lindeman B., Instanes C., Brunborg B., & Schwarze P. Health effects of amines and derivatives associated with CO2 capture. Norwegian Institute of Public Health: 2011
  48. ^ Coppola A., Montagnaro F., Salatino P., Scala F. Fluidized bed calcium looping: The effect of CO2 on sorbent attrition and CO2 capture capacity, Chemical Engineering Journal, Volumes 207–208, 1 October 2012, 445-449
  49. ^ Cormos A.M.; Simon A. (2013). "Dynamic modeling of CO2 capture by calcium-looping cycle". Chemical Engineering Transactions. 35: 421–426. doi:10.3303/CET1335070.2 capture by calcium-looping cycle&rft.volume=35&rft.pages=421-426&rft.date=2013&rft_id=info:doi/10.3303/CET1335070&rft.au=Cormos A.M.&rft.au=Simon A.&rft_id=https://doi.org/10.3303/CET1335070&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  50. ^ Hanak, Dawid P.; Biliyok, Chechet; Manovic, Vasilije (2016). "Calcium looping with inherent energy storage for decarbonisation of coal-fired power plant". Energy & Environmental Science. 9 (3): 971–983. doi:10.1039/C5EE02950C.
  51. ^ a b Blamey, J.; Anthony, E.J.; Wang, J.; Fennell, P.S. (2010). "The calcium looping cycle for large-scale CO2 capture". Progress in Energy and Combustion Science. 36 (2): 260–279. doi:10.1016/j.pecs.2009.10.001.
  52. ^ Hanak, D.; Biliyok, C; Anthony, E; Manovic, V. "Modelling and comparison of calcium looping and chemical solvent scrubbing retrofits for CO2 capture from coal-fired power plant". International Journal of Greenhouse Gas Control. 2015: 226–236.2 capture from coal-fired power plant&rft.volume=2015&rft.pages=226-236&rft.aulast=Hanak&rft.aufirst=D.&rft.au=Biliyok, C&rft.au=Anthony, E&rft.au=Manovic, V.&rfr_id=info:sid/en.wikipedia.org:Calcium looping" class="Z3988">
  53. ^ Hanak D., Biliyok C, Manovic V. Calcium looping with inherent energy storage for decarbonization of coal-fired power plant. Energy and Environmental Science 2016
  54. ^ EIA. Electricity: Electricity Generating Capacity (2013). http://www.eia.gov/electricity/capacity/
  55. ^ USGS Mineral Resources Program. Cement. <http://minerals.usgs.gov/minerals/pubs/commodity/cement/170400.pdf>